Deckentiefkühlaggregat Premium Plug-In 770W bis 6m³, 400V, 50Hz

GOVI

Ceiling-mounted freezer unit Premium plug-in 770W up to 6m³, 400V, 50Hz

€4.849,00

Trade prices and VAT treatment are displayed according to your customer status and checkout settings.

Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.

Power & connection

  • Refrigeration capacity: 1099 W
  • Electrical connection: 0.770 kW, 230 V / 50 Hz

Areas of application

  • Cell volume: —
    • Ambient temperature: 32 °C
    • Internal temperature: –25 °C
  • Cell volume: 6 m³
    • Ambient temperature: 32 °C
    • Internal temperature: –20 °C
  • Cell volume: 8 m³
    • Ambient temperature: 32 °C
    • Internal temperature: –15 °C

Dimensions & weight

  • Dimensions (WxDxH): 678 × 1053 × 527 mm
  • Weight: 86 kg

Equipment

  • CFC-free refrigerant R455A (GWP = 148)
  • Cable for cold room lighting
  • 2 m power cable (without plug)
  • Cable for door contact switch
  • Suitable as a piggyback unit or wall-mounted plug-in unit (with plug-in kit)
  • Remote control with 5 m cable

Product features

Ceiling mounting | Deep freezing | -25° to -15°C | Connection for door frame heating and cold room lighting | Remote control with 5m cable

Technical data

ManufacturerGOVI
Article numberATD-61
EAN4262514548423
Dimensions W x D x H (mm)678x1053x527
Width (mm)678
Depth (mm)1053
Height (mm)527
Colourwhite
Controlelectronic
Electrical connection230V/50Hz
Voltage (V)230
Current (A)4
Power (kW)0.77
Net weight (kg)86
Gross weight (kg)98
Packaging dimensions W x D x H (mm)1100x700x980
Installation typeCeiling mounting
Type of coolingFreezer
Automatic defrostyes
RefrigerantR455A
Ambient temperature32°C
Temperature range (°C)-25°C to -15°C
Refrigeration capacity (kW)1.1
Delivery time14-21 working days
Shipping methodFreight forwarding
Country of originGermany

Downloads

Product safety

Responsible person (EU): GOVI GmbH, Max-Planck-Str. 5, 53842 Troisdorf (Germany), info@govi-gmbh.de

Safety instructions:

  • Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
  • Before first use, remove all protective films and clean the appliance carefully
  • The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
  • Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
  • When not in use, the appliance must be switched off and disconnected from the mains
  • Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
  • Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
  • In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
  • After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
  • Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
  • The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
  • Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
  • The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
  • To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
  • Do not place corrosive acids or alkalis in the appliance. Thermik
  • The appliance must never be positioned near flammable materials or heat sources.
  • A safety distance of at least 20 cm on all sides must be maintained.
  • Only use the appliance with an earthed power connection and check the power cable regularly for damage.
  • The appliance is not suitable for outdoor use or use in the rain.
  • Surfaces can become hot during operation – use protective measures such as gloves.
  • In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Need a volume price or project quotation? Talk to us ↗

Professional use
Our team can help with technical specifications and warranty conditions.

Delivery and installation
Availability and options depend on the product and delivery address.