€7.669,00
Trade prices and VAT treatment are displayed according to your customer status and checkout settings.
Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.
Refrigerated display counter Gastroline with tray rail Colour: black - other colours optionally available with internal refrigeration unit Version with tray rail Temperature range: +2°C to +8°C Dimensions (WxDxH): 2000 x 900 x 850/1250 +/-10 mm Volume: 726 litres Refrigerant: R290 Rated power: 230V / 50Hz Cooling capacity: 684 watts Internal refrigeration unit Dynamic cooling Outer casing made of black-coated sheet metal Front strip made entirely of melamine – colour selection possible (colour samples) Upper glass top unit with straight front pane Frame for GN containers Base unit made of white-coated sheet metal with height-adjustable shelf Rear hinged door Environmentally friendly polyurethane foam insulation Grey granite worktop (thickness: 30mm) Additional upper interior lighting – LED automatic defrosting Automatic condensate evaporation Electronic temperature control with digital display Audible signal to report contamination of the evaporator or blockage of the fan
Product features
Temperature range: +2°C/+8°C Refrigeration unit: internal Melamine front strip Exterior cladding made of black-coated sheet metal Grey granite worktop 30 mm Upper glass top with straight front pane LED lighting Automatic defrost Automatic condensate evaporation Electronic temperature control with digital display Version with tray slide
Technical data
| Manufacturer | Igloo |
| Article number | GL102T-90 |
| EAN | 4262494985126 |
| Dimensions W x D x H (mm) | 2500x900x850/1250 |
| Width (mm) | 2500 |
| Depth (mm) | 900 |
| Height (mm) | 850/1250 |
| Gross capacity (L) | 726 |
| Colour | black |
| Material | Plastic, glass, coated sheet metal, stainless sheet metal, wood |
| Control | electronic |
| Voltage (V) | 230 |
| Power (kW) | 0.7 |
| Installation type | Freestanding unit |
| Type of cooling | Dynamic cooling |
| Automatic defrost | yes |
| Refrigerant | R290 |
| Temperature range (°C) | 2°C / +8°C |
| Lighting | yes |
| Scope of delivery | 1 piece(s) |
| Delivery time | 6-8 weeks |
| Shipping method | Freight forwarding |
| Country of origin | Europe |
Product safety
Responsible person (EU): „IGLOO“ IGLOO Sp. z o.o., Stary Wiśnicz 289, 32-720 Nowy Wiśnicz, Poland, info@igloo.pl
Safety instructions:
- Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
- Before first use, remove all protective films and clean the appliance carefully
- The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
- Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
- When not in use, the appliance must be switched off and disconnected from the mains
- Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
- Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
- In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
- After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
- Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
- The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
- Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
- The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
- To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
- Do not place corrosive acids or alkalis in the appliance. Thermik
- The appliance must never be positioned near flammable materials or heat sources.
- A safety distance of at least 20 cm on all sides must be maintained.
- Only use the appliance with an earthed power connection and check the power cable regularly for damage.
- The appliance is not suitable for outdoor use or use in the rain.
- Surfaces can become hot during operation – use protective measures such as gloves.
- In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Professional use
Our team can help with technical specifications and warranty conditions.
Delivery and installation