Refrigerated counter External dimensions (WxDxH): 2330 x 700 x 850 mm Internal dimensions (WxDxH): 1760 x 562 x 605 mm Packaging dimensions (WxDxH): 2430 x 800 x 1000 mm Volume: 632 litres Gross weight: 205 kg | Net weight: 185 kg Material: Stainless steel inside and outside Insulation: 50 mm polyurethane Refrigerant: R290 Energy label class: A Temperature range: -2 °C to +8 °C Maximum outside temperature: 43 °C at 65% humidity Energy consumption per day: 1.317 kWh Power: 350 W, 240 V, 50 Hz Functions: Digital temperature display, automatic defrosting Includes upstand
Product features
robust and durable construction, 700mm depth, environmentally friendly cooling with refrigerant 290a, all variants (door, 2-drawer units, 3-drawer units) possible
Technical data
| Manufacturer | A&S Gastro |
| Article number | KT4ZZZZA |
| EAN | 4061794537642 |
| Dimensions W x D x H (mm) | 2330x700x850 |
| Width (mm) | 2330 |
| Depth (mm) | 700 |
| Height (mm) | 850 |
| Internal width (mm) | 1760 |
| Internal depth (mm) | 562 |
| Internal height (mm) | 605 |
| Net volume (litres) | 632 |
| Net capacity (L) | 632 |
| Gross capacity (L) | 632 |
| Colour | Silver |
| Material | Stainless steel |
| Interior material | Stainless steel |
| Insulation (mm) | 50 |
| Control | digital |
| Electrical connection | 240 V/50 Hz |
| Voltage (V) | 240 |
| Power (kW) | 0.3 |
| Energy consumption (kWh/24h) | 1.3 |
| Energy consumption per year (kWh) | 481 |
| EU regulation | 2015/1094-IV |
| Energy efficiency class | A |
| EPREL-ID | 2142241 |
| Net weight (kg) | 185 |
| Gross weight (kg) | 205 |
| Packaging dimensions W x D x H (mm) | 2510 x 800 x 1000 |
| Number of doors | 0 |
| Installation type | Freestanding unit |
| Type of cooling | dynamic |
| Automatic defrost | yes |
| Refrigerant | R290 |
| Ambient temperature | 43°C |
| Temperature range (°C) | -2 - +8 |
| Refrigeration capacity (kW) | 0.35 |
| Upstand | JA |
| Scope of delivery | 1 piece(s) |
| Delivery time | 1-5 working days |
| Shipping method | Freight forwarding |
| Country of origin | Europe |
Downloads
Product safety
Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de
Safety instructions:
- Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
- Before first use, remove all protective films and clean the appliance carefully
- The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
- Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
- When not in use, the appliance must be switched off and disconnected from the mains
- Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
- Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
- In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
- After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
- Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
- The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
- Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
- The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
- To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
- Do not place corrosive acids or alkalis in the appliance. Thermik
- The appliance must never be positioned near flammable materials or heat sources.
- A safety distance of at least 20 cm on all sides must be maintained.
- Only use the appliance with an earthed power connection and check the power cable regularly for damage.
- The appliance is not suitable for outdoor use or use in the rain.
- Surfaces can become hot during operation – use protective measures such as gloves.
- In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Professional use
Our team can help with technical specifications and warranty conditions.
Delivery and installation
Availability and options depend on the product and delivery address.