A&S Polarny
Cold room 1800x1500x2010 mm without refrigeration unit
€3.399,00
Trade prices and VAT treatment are displayed according to your customer status and checkout settings.
Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.
WxDxH: 1800x1500x2010 mm Volume: 4.0 m³ matching refrigeration unit available on request coated sheet steel inside and outside with additional PVC coating on the inside Colour: white Insulation: polyurethane foam 80 mm Stainless steel cold room floor AISI430 (non-slip) Easy to clean Easy assembly thanks to panel system Lockable door with safety lock Stainless steel door threshold Door hinged on the right (reversible) Clear door size: 1845x700 mm Door seal profile: PVC silicone seals Optional lighting Static load: 2000 kgf/m2 Material complies with food standards Product certified to ISO9001 Modular wall and ceiling sections made of galvanised sheet steel with polymer coating
Product features
Interior and exterior made of coated sheet steel Interior with additional PVC coating Insulation: polyurethane foam 80 mm Door with right-hand hinge Stainless steel cell floor AISI304 (non-slip) Easy assembly thanks to panel system Door lockable with safety lock
Technical data
| Manufacturer | A&S Gastro |
| Article number | KZ1815 |
| EAN | 4061794538304 |
| Dimensions W x D x H (mm) | 1800x1500x2010 |
| Width (mm) | 1800 |
| Depth (mm) | 1500 |
| Height (mm) | 2010 |
| Internal width (mm) | 1640 |
| Internal depth (mm) | 1340 |
| Internal height (mm) | 1841 |
| Volume (m³) | 4 |
| Colour | white |
| Material | galvanised sheet steel Insulation polyurethane foam Cell floor stainless steel AISI304 (non-slip) |
| Interior material | PVC coating |
| Floor material | Stainless steel AISI304 (non-slip) |
| Insulation (mm) | 80 |
| Net weight (kg) | 249 |
| Gross weight (kg) | 259 |
| Packaging dimensions W x D x H (mm) | 1300x2000x1200mm |
| Number of doors | 1 |
| Type of doors | Hinged door |
| Door dimensions W x H (mm) | 700x1845 |
| Lockable | yes |
| Hinge left/right | right |
| Reversible door hinge | yes |
| Installation type | Freestanding unit |
| Ambient temperature | 32°C |
| Temperature range (°C) | -5°C to +5°C |
| Design type | Panel system |
| Scope of delivery | 1 piece(s) |
| Delivery time | 1-5 working days |
| Shipping method | Freight forwarding |
| Country of origin | Europe |
Product safety
Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de
Safety instructions:
- Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
- Before first use, remove all protective films and clean the appliance carefully
- The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
- Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
- When not in use, the appliance must be switched off and disconnected from the mains
- Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
- Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
- In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
- After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
- Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
- The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
- Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
- The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
- To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
- Do not place corrosive acids or alkalis in the appliance. Thermik
- The appliance must never be positioned near flammable materials or heat sources.
- A safety distance of at least 20 cm on all sides must be maintained.
- Only use the appliance with an earthed power connection and check the power cable regularly for damage.
- The appliance is not suitable for outdoor use or use in the rain.
- Surfaces can become hot during operation – use protective measures such as gloves.
- In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Professional use
Our team can help with technical specifications and warranty conditions.
Delivery and installation
Availability and options depend on the product and delivery address.