Kühlzelle 2.400x1.500x2.210 mm ohne Aggregat | Volumen 6,1 m³ | WS 80 mmKühlzelle 2.400x1.500x2.210 mm ohne Aggregat | Volumen 6,1 m³ | WS 80 mmKühlzelle 2.400x1.500x2.210 mm ohne Aggregat | Volumen 6,1 m³ | WS 80 mmKühlzelle 2.400x1.500x2.210 mm ohne Aggregat | Volumen 6,1 m³ | WS 80 mm

A&S Polarny

Cold room 2,400x1,500x2,210 mm without refrigeration unit | Volume 6.1 m³ | WS 80 mm

€5.299,00

Trade prices and VAT treatment are displayed according to your customer status and checkout settings.

Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.

Cold room 2,400x1,500x2,210 mm – without refrigeration unit | Volume 6.1 m³

High-quality cold room "Made in Germany" including on-site installation “ for catering, hotels and food businesses. With strong insulation, hygienic surfaces and a robust floor – energy-saving, safe and quick to assemble.

Highlights
* Save energy: 80 mm PU insulation for maximum cooling efficiency and lower energy costs
* Maximum hygiene: Powder-coated surfaces & stainless steel make cleaning easy
* Safe working: Non-slip R 11 stainless steel floor, load capacity up to 20 kN/m²
* Quick assembly: Cam locks & modular panel construction for straightforward set-up
* Flexible door solution: Lockable door with magnetic seal, hinges changeable between DIN-L/DIN-R
* Food-safe: Developed to food industry standards
* Reliable quality: Made in Germany, EU-compliant, ISO 9001 certified

Technical data
* Dimensions (WxDxH): 2,400x1,500x2,210 mm
* Internal volume: 6.1 m³
* Wall thickness: 80 mm, PU foam (cyclo/isopentane-foamed)
* Wall & ceiling material: Powder-coated, galvanised sheet steel
* Floor: powder-coated sheet steel outside, stainless steel inside, R 11 floor classification, up to 20 kN/m²
* Door: Single-leaf, lockable, magnetic seal, stainless steel threshold, hinges reversible (DIN-L & DIN-R)
* Assembly: Cam-lock system, modular panel construction
* Design: Food-safe, manufactured in accordance with EU regulations
* including on-site installation

Product features

• Quick assembly thanks to cam-locks

• Hygienic thanks to durable powder coating (walls, ceiling, floor, door)

• Safe & compliant with standards: Made in Germany, EU regulations, R 11 floor classification

• Energy-efficient with quick cost amortisation

• Walls & ceiling: powder-coated, galvanised sheet steel, PU foam

• Floor: powder-coated sheet steel outside, stainless steel inside, load capacity up to 20 kN/m²

• Door: powder-coated sheet steel, reversible hinges (DIN-L & DIN-R)

Technical data

ManufacturerA&S Gastro
Article numberKZ2415220_PREMIUM
EAN4262514529446
Dimensions W x D x H (mm)2.400x1.500x2.210
Width (mm)2400
Depth (mm)1500
Height (mm)2210
Internal width (mm)2240
Internal depth (mm)1340
Internal height (mm)2050
Volume (m³)6.1
Colourwhite
MaterialPowder-coated galvanised sheet steel, cyclo/isopentane foamed PU, stainless steel cell floor inside
Floor materialPowder-coated galvanised sheet steel outside, stainless steel inside
Insulation (mm)80
Net weight (kg)305
Gross weight (kg)315
Packaging dimensions W x D x H (mm)2450x1215
Number of doors1
Type of doorsHinged door
Door dimensions W x H (mm)700x1850
Lockableyes
Hinge left/rightright
Reversible door hingeyes
Installation typeFreestanding unit
Ambient temperature32°C
Temperature range (°C)-5°C to +5°C
Design typePanel system
Scope of delivery1 piece(s)
Delivery time1-5 working days
Shipping methodFreight forwarding
Country of originGermany

Downloads

Product safety

Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de

Safety instructions:

  • Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
  • Before first use, remove all protective films and clean the appliance carefully
  • The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
  • Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
  • When not in use, the appliance must be switched off and disconnected from the mains
  • Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
  • Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
  • In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
  • After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
  • Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
  • The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
  • Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
  • The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
  • To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
  • Do not place corrosive acids or alkalis in the appliance. Thermik
  • The appliance must never be positioned near flammable materials or heat sources.
  • A safety distance of at least 20 cm on all sides must be maintained.
  • Only use the appliance with an earthed power connection and check the power cable regularly for damage.
  • The appliance is not suitable for outdoor use or use in the rain.
  • Surfaces can become hot during operation – use protective measures such as gloves.
  • In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Need a volume price or project quotation? Talk to us ↗

Professional use
Our team can help with technical specifications and warranty conditions.

Delivery and installation
Availability and options depend on the product and delivery address.