Kühlzelle 3000x2400x2010 mm inkl. Kühlaggregat und Regal

A&S Polarny

Cold room 3000x2400x2010 mm incl. refrigeration unit and shelf

€10.707,00

Trade prices and VAT treatment are displayed according to your customer status and checkout settings.

Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.

Technical data: Dimensions (WxDxH): 3000x2400x2010 mm Volume: 11.8 m³ Material: Coated sheet steel inside and outside, interior with additional PVC coating, colour: white Insulation: polyurethane foam 80 mm Cold room floor: Stainless steel AISI430 (non-slip) Cleaning: Easy cleaning Construction: Easy assembly thanks to panel system Door: Lockable with safety lock, stainless steel threshold, door hinge on the right (reversible) Clear door size: 1845x700 mm Seals: PVC silicone seals Static load: 2000 kgf/m² Material standards: Complies with food standards, certified to ISO 9001 Modular wall and ceiling sections: Made of galvanised sheet steel with polymer coating Refrigeration unit: Temperature range: –5 °C to +5 °C Voltage: 230 V Refrigerant: R 290 A Refrigeration unit: plug-in installation, 810 W, 230 V, 50 Hz Cell volume: 6.7 m³ at ambient temperature 32 °C and internal temperature –5 °C 9.6 m³ at ambient temperature 32 °C and internal temperature 0 °C 13.6 m³ at ambient temperature 32 °C and internal temperature +5 °C Electrical connection: 230 V, 50 Hz Refrigeration unit dimensions: Dimensions (WxDxH): 720x400x795 mm Weight: 47 kg Refrigerated shelving: Shelf dimensions: 2428x370x1670 mm 1810x370x1670 mm Material: Anodised aluminium, L-shaped Load capacity: max. 90 kg per level, 450 kg per shelf unit Height: 1680 mm (4 levels), height increments: 150 mm Assembly: Easy tool-free assembly Temperature resistance: –30 °C to +60 °C Material: Food-safe materials, removable shelf inserts, dishwasher-safe up to 90 °C Areas of use: Suitable for cold rooms (down to –30 °C), laboratories, clean rooms, commercial kitchens, storage rooms, dry goods storage Hygiene: Compliant with cleaning and hygiene requirements Warranty: Rust-free guarantee thanks to anodised aluminium

Product features

Interior and exterior made of coated sheet steel Interior with additional PVC coating Insulation: polyurethane foam 80 mm Door with right-hand hinge Stainless steel cell floor AISI304 (non-slip) Easy assembly thanks to panel system Door lockable with safety lock

Technical data

ManufacturerA&S Gastro
Article numberKZ3024 + KA-18 + KR3024
EAN4061794538519
Dimensions W x D x H (mm)3000x2400x2010
Width (mm)3000
Depth (mm)2400
Height (mm)2010
Internal width (mm)2840
Internal depth (mm)2240
Internal height (mm)1841
Volume (m³)11.6
Colourwhite
Materialgalvanised sheet steel Insulation polyurethane foam Cell floor stainless steel AISI304 (non-slip)
Interior materialPVC coating
Floor materialStainless steel AISI304 (non-slip)
Insulation (mm)80
Controlelectronic
Electrical connection230V/50Hz
Voltage (V)230
Power (kW)0.8
Net weight (kg)413
Gross weight (kg)419
Packaging dimensions W x D x H (mm)2600x2000x1300 + 880x490x880 + 420x250x1750 + 420x250x1750
Number of doors1
Type of doorsHinged door
Door dimensions W x H (mm)700x1845
Lockableyes
Hinge left/rightright
Reversible door hingeyes
Installation typeFreestanding unit
Automatic defrostyes
RefrigerantR290
Ambient temperature32°C
Temperature range (°C)-5°C to +5°C
Number of feet4
Number of tiers4
Bottom shelfyes
Intermediate shelfyes
Design typePanel system
Scope of delivery3 components
Delivery time1-5 working days
Shipping methodFreight forwarding
Country of originEurope

Product safety

Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de

Safety instructions:

  • Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
  • Before first use, remove all protective films and clean the appliance carefully
  • The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
  • Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
  • When not in use, the appliance must be switched off and disconnected from the mains
  • Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
  • Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
  • In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
  • After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
  • Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
  • The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
  • Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
  • The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
  • To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
  • Do not place corrosive acids or alkalis in the appliance. Thermik
  • The appliance must never be positioned near flammable materials or heat sources.
  • A safety distance of at least 20 cm on all sides must be maintained.
  • Only use the appliance with an earthed power connection and check the power cable regularly for damage.
  • The appliance is not suitable for outdoor use or use in the rain.
  • Surfaces can become hot during operation – use protective measures such as gloves.
  • In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Need a volume price or project quotation? Talk to us ↗

Professional use
Our team can help with technical specifications and warranty conditions.

Delivery and installation
Availability and options depend on the product and delivery address.