Tiefkühlzelle Wandstärke 120mm, 1800x1800x2010 mm, ohne Aggregat

A&S Polarny

Freezer room wall thickness 120mm, 1800x1800x2010 mm, without refrigeration unit

€4.799,00

Trade prices and VAT treatment are displayed according to your customer status and checkout settings.

Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.

Technical data: Dimensions (WxDxH): 1800x1800x2010 mm Volume: 4.3 m³ Clear door size: 700x1765 mm Material: Coated sheet steel inside and outside, interior with additional PVC coating, colour: white Insulation: polyurethane foam 120 mm Cold room floor: Stainless steel AISI430 (non-slip) Cleaning: Easy cleaning Construction: Easy assembly thanks to panel system Door: Lockable with safety lock, door hinge on the right (reversible) Door threshold: Stainless steel Door seal profile: PVC silicone seals Static load: 2000 kgf/m² Material standards: Complies with food standards Product certification: Certified to ISO 9001 Wall and ceiling sections: Modular wall and ceiling sections made of galvanised sheet steel with polymer coating Refrigeration unit: Matching unit: Available on request

Product features

Interior and exterior made of coated sheet steel Interior with additional PVC coating Insulation: polyurethane foam 120 mm Door with right-hand hinge Stainless steel cell floor AISI304 (non-slip) Easy assembly thanks to panel system Door lockable with safety lock

Technical data

ManufacturerA&S Gastro
Article numberTKZ1818
EAN4061794538250
Dimensions W x D x H (mm)1800x1800x2010
Width (mm)1800
Depth (mm)1800
Height (mm)2010
Internal width (mm)1560
Internal depth (mm)1560
Internal height (mm)1770
Volume (m³)4.3
Colourwhite
Materialcoated sheet steel Insulation polyurethane foam Cell floor stainless steel AISI304 (non-slip)
Interior materialPVC coating
Floor materiallacquered sheet steel
Insulation (mm)120
Net weight (kg)260
Gross weight (kg)280
Packaging dimensions W x D x H (mm)1500x2000x1480
Number of doors1
Type of doorsHinged door
Door dimensions W x H (mm)700X1765
Lockableyes
Hinge left/rightright
Reversible door hingeyes
Installation typeFreestanding unit
Temperature range (°C)-15°C / 20°C
Design typePanel system
Scope of delivery1 piece(s)
Delivery time1-5 working days
Shipping methodFreight forwarding
Country of originEurope

Product safety

Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de

Safety instructions:

  • Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
  • Before first use, remove all protective films and clean the appliance carefully
  • The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
  • Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
  • When not in use, the appliance must be switched off and disconnected from the mains
  • Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
  • Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
  • In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
  • After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
  • Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
  • The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
  • Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
  • The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
  • To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
  • Do not place corrosive acids or alkalis in the appliance. Thermik
  • The appliance must never be positioned near flammable materials or heat sources.
  • A safety distance of at least 20 cm on all sides must be maintained.
  • Only use the appliance with an earthed power connection and check the power cable regularly for damage.
  • The appliance is not suitable for outdoor use or use in the rain.
  • Surfaces can become hot during operation – use protective measures such as gloves.
  • In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Need a volume price or project quotation? Talk to us ↗

Professional use
Our team can help with technical specifications and warranty conditions.

Delivery and installation
Availability and options depend on the product and delivery address.