Tiefkühlzelle Wandstärke 120mm, 2700x3000x2200 mm,  inkl. Kühlaggregat und Regal

A&S Polarny

Freezer room wall thickness 120mm, 2700x3000x2200 mm, incl. refrigeration unit and shelf

€14.107,00

Trade prices and VAT treatment are displayed according to your customer status and checkout settings.

Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.

WxDxH: 2700x3000x2200 mm Volume: 13.31 m³ Internal dimensions WxDxH: 2460x2760x1960 mm painted sheet steel inside and outside Colour: white Insulation: pressure-injected polyurethane foam 120 mm Stainless steel cold room floor (non-slip) Easy to clean Easy assembly thanks to panel system Lockable door with safety lock, heated door seal, Clear door size: 700x1765 mm Stainless steel door threshold Door hinged on the right Refrigeration unit: - Wall mounting - Plug-in installation - Dimensions WxDxH: 750x870x824 mm - Power: 1650 W - 230 V / 50 Hz - 8.8 Ampere - Net weight: 92 kg - Gross weight: 97 kg - Capacity: 5.5 - 14.6 m³ Cell volume: 5.5 m³ - Ambient temperature: 32 °C - Internal temperature: - 25 °C Cell volume: 8.6 m³ - Ambient temperature: 32 °C - Internal temperature: - 20 °C Cell volume: 14.6 m³ - Ambient temperature: 32 °C - Internal temperature: - 15 °C - Temperature range: -15°C to -25°C - Ambient temperature: up to +43°C - Room humidity: up to 60 % - Packaging dimensions: 960x750x990 mm - Fan-assisted cooling - Connecting cable 1.5 m - Environmentally friendly ECO refrigerant R290 - Compact and practical design - Simple and quick installation - Hermetic compressors with thermal motor protection - Automatic hot-gas defrosting - Electronic temperature control - Energy-efficient - High quality and reliability - Long service life - Excellent value for money Shelf: • Shelf dimensions: 2269x2598x1680 mm • Shelving system made of anodised aluminium • L-shaped • maximum load 90 kg per level / 450 kg per shelf unit • Height: 1680 mm (4 levels) • Height increments: 150 mm • easy to assemble without tools • Temperature resistance: -30 to +60 °C • Height increments: 150 mm • Made from food-safe materials • Shelf boards made of polymer plastic • removable shelf inserts can be cleaned in the dishwasher at up to 90°C • Compliant with cleaning and hygiene requirements • Suitable for cold rooms (down to -30 °C), laboratories & clean rooms, commercial kitchens, storage rooms & dry storage • Manufactured in accordance with hygiene and safety guidelines • Material complies with European food standards • Rust-free guarantee thanks to anodised aluminium

Product features

Interior and exterior made of coated sheet steel Interior with additional PVC coating Insulation: polyurethane foam 120 mm Door with right-hand hinge Stainless steel cell floor AISI304 (non-slip) Easy assembly thanks to panel system Door lockable with safety lock"

Technical data

ManufacturerA&S Gastro
Article numberTKZ2730-220 + TA-27 + TKR2730
EAN4262446052272
Dimensions W x D x H (mm)2700x3000x2200
Width (mm)2700
Depth (mm)3000
Height (mm)2200
Internal width (mm)2460
Internal depth (mm)2760
Internal height (mm)1960
Volume (m³)13.3
Colourwhite
Materialcoated sheet steel Insulation polyurethane foam Cell floor stainless steel AISI304 (non-slip)
Interior materialPVC coating
Floor materialStainless steel AISI304 (non-slip)
Insulation (mm)120
Controlelectronic
Electrical connection230V/50Hz
Voltage (V)230
Current (A)4.7
Power (kW)1
Net weight (kg)702
Gross weight (kg)722
Packaging dimensions W x D x H (mm)2800x1900x1200
Number of doors1
Type of doorsHinged door
Door dimensions W x H (mm)700X1765
Lockableyes
Hinge left/rightright
Reversible door hingeyes
Installation typeFreestanding unit
Type of coolingForced air
Automatic defrostyes
RefrigerantR452A
Ambient temperature32°C
Temperature range (°C)0°C / -20°C
Refrigeration capacity (kW)1
Number of feet4
Number of tiers4
Bottom shelfyes
Intermediate shelfyes
Design typePanel system
Scope of delivery3 components
Delivery time1-5 working days
Shipping methodFreight forwarding
Country of originEurope

Product safety

Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de

Safety instructions:

  • Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
  • Before first use, remove all protective films and clean the appliance carefully
  • The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
  • Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
  • When not in use, the appliance must be switched off and disconnected from the mains
  • Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
  • Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
  • In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
  • After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
  • Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
  • The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
  • Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
  • The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
  • To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
  • Do not place corrosive acids or alkalis in the appliance. Thermik
  • The appliance must never be positioned near flammable materials or heat sources.
  • A safety distance of at least 20 cm on all sides must be maintained.
  • Only use the appliance with an earthed power connection and check the power cable regularly for damage.
  • The appliance is not suitable for outdoor use or use in the rain.
  • Surfaces can become hot during operation – use protective measures such as gloves.
  • In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Need a volume price or project quotation? Talk to us ↗

Professional use
Our team can help with technical specifications and warranty conditions.

Delivery and installation
Availability and options depend on the product and delivery address.