Tiefkühltruhe  |  mit geschlossenem Edelstahl-Deckel und Beleuchtung  | 620 LiterTiefkühltruhe  |  mit geschlossenem Edelstahl-Deckel und Beleuchtung  | 620 Liter

A&S Polarny

Chest freezer | with closed stainless steel lid and lighting | 620 litres

€1.449,00

Trade prices and VAT treatment are displayed according to your customer status and checkout settings.

Prices can be viewed without registering. Create a professional account to request professional offers and tailored terms.

Chest freezer with stainless steel lid

  • Gross volume: 620 litres
  • Net volume: 600 litres

Equipment

  • Lid: Closed solid lid with handle and lock
  • Lighting: Interior lighting
  • Baskets: 2 removable wire baskets

Temperature & cooling

  • Temperature control: Mechanical thermostat
  • Refrigerant: R600a (environmentally friendly)

Material & workmanship

  • Outer housing: Galvanised sheet, white lacquered
  • Lid: Stainless steel (inox silver)
  • Inner housing: Aluminium

Product features

Gross volume: 620 litres, Net volume: 600 litres, Stainless steel solid lid with handle and lock, Refrigerant R600a, Interior lighting, Mechanical thermostat, 2 removable wire baskets, Exterior housing: Galvanised sheet white lacquered - Stainless steel lid inox-silver, Aluminium inner housing, LED lighting, Total power 0.2 kW, Temperature range: -24/+6°C, Cooling: Static

Technical data

ManufacturerA & S Gastro
Article numberTTV-620 INOX
EAN4262514514541
Dimensions W x D x H (mm)1904x743x840
Width (mm)1904
Depth (mm)743
Height (mm)840
Internal width (mm)1777
Internal depth (mm)528
Internal height (mm)668
Net volume (litres)600
Net capacity (L)600
Gross capacity (L)620
ColourWhite-silver
MaterialStainless steel, metal, plastic
Insulation (mm)60
Controlelectronic
Electrical connection230V/50Hz
Voltage (V)230
Current (A)0.9
Power (kW)0.2
Energy consumption (kWh/24h)2.3
Energy consumption per year (kWh)825
EU regulation2019/2018
Energy efficiency classC
EPREL-ID1860269
Net weight (kg)72
Gross weight (kg)79
Packaging dimensions W x D x H (mm)1957x777x880
Lockableyes
Installation typeFreestanding unit
Type of coolingStatic
Automatic defrost-
RefrigerantR600a
Ambient temperature+16°/+40°
Temperature range (°C)-24°/+6°C
Lightingyes
Number of baskets2
Scope of delivery1 piece(s)
Delivery time1-5 working days
Shipping methodFreight forwarding
Country of originTR

Downloads

Product safety

Responsible person (EU): "Polarny" A&S Gastro GmbH & Co. KG, Möhnestr. 139a, 59755 Arnsberg, info@aundsgastro.de

Safety instructions:

  • Make sure the appliance stands on a stable, horizontal, level, heat-resistant and non-slip surface
  • Before first use, remove all protective films and clean the appliance carefully
  • The appliance must not be operated or adjusted by unauthorised persons (e.g. children)
  • Please note that the appliance must never be cleaned with a jet of water or immersed in liquids; there is an acute risk of electric shock and short circuit. The appliance must also be switched off and disconnected from the mains before cleaning/maintenance
  • When not in use, the appliance must be switched off and disconnected from the mains
  • Damaged cables or plugs must not be used. These parts may only be replaced by qualified specialist personnel.
  • Extension cables, adapters or multi-socket strips must not be used, as this can lead to overheating. There is an acute risk of fire
  • In the event of a power failure or disconnection from the mains, wait at least 5 minutes before switching the appliance back on to avoid damage Refrigeration appliances
  • After transport or when the appliance is moved, it must be left switched off for 24 hours before it may be switched on
  • Make sure that sufficient air can be supplied to the appliance by keeping ventilation grilles and openings clear so that enough air can circulate
  • The appliance must not be placed in the immediate vicinity of heat sources. Likewise, the appliance must not be located in damp rooms or in direct sunlight
  • Ice cube machines are intended exclusively for making ice cubes. Other uses may cause damage and affect the warranty.
  • The refrigerant used is a flammable and explosive gas. If the refrigerant circuit is damaged, the room must be well ventilated and open flames avoided.
  • To prevent a flammable gas-air mixture from forming due to a leaking refrigeration circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is stated on the rating plate inside the housing.
  • Do not place corrosive acids or alkalis in the appliance. Thermik
  • The appliance must never be positioned near flammable materials or heat sources.
  • A safety distance of at least 20 cm on all sides must be maintained.
  • Only use the appliance with an earthed power connection and check the power cable regularly for damage.
  • The appliance is not suitable for outdoor use or use in the rain.
  • Surfaces can become hot during operation – use protective measures such as gloves.
  • In the event of fire, never use water, but suitable extinguishing agents (e.g. C14)
Need a volume price or project quotation? Talk to us ↗

Professional use
Our team can help with technical specifications and warranty conditions.

Delivery and installation
Availability and options depend on the product and delivery address.